Skip to content
Free US shipping over $100
Free US shipping over $100

Venous Serum Blood Collection Tubes, BD Vacutainer Plus Red Top Tube with Clot Activator 6 mL Hemogard Closure 100/Box

by BD
Sale 35%
Original price $ 52.00
Current price $ 34.00
SKU 367815

The Ultimate Blood Collection Tube for Precise Serum Results, Laboratory Safety, and Efficient Workflow

Experience superior accuracy and safety in every blood draw with BD Vacutainer Plus Venous Serum Blood Collection Tubes with Clot Activator, 6 mL with Hemogard Closure, 100/Box. Trusted by top hospitals, clinical laboratories, and phlebotomy professionals worldwide, these serum separator tubes optimize sample integrity and streamline blood collection for clinical chemistry, serology, immunology, and advanced laboratory diagnostics.

Why BD Vacutainer Plus Venous Serum Blood Collection Tubes are #1 in Laboratories

  • Advanced Clot Activator Technology: Each tube contains a silica-based clot activator for rapid and complete clotting, ensuring high-quality serum separation and maximum analyte recovery during centrifugation.
  • Hemogard™ Closure for Enhanced Safety: Patented BD Hemogard closure virtually eliminates contact with blood, protecting healthcare workers from splashes, spills, and contamination, while offering robust leak resistance during handling and transport.
  • Consistent Sample Quality: Pre-measured 6 mL fill guarantees optimal serum yield for multiple tests—no more redraws or compromised results.
  • Universal Compatibility: Standard size and Hemogard cap fit all leading blood collection systems, automation, and analyzers for seamless workflow integration.
  • Latex-Free & Sterile: Designed for patient safety, these tubes are latex-free and rigorously sterilized, making them ideal for all patient populations, including those with sensitivities.

Technology Highlights

  • Clot Activator: Fine silica particles coated inside the tube’s walls accelerate the blood clotting process, reliably producing a clear, cell-free serum, essential for accurate laboratory reporting.
  • Vacuum Sealed: Precision vacuum ensures proper blood draw volume for standardized medical results.
  • Hemogard™ Closure: This advanced closure system prevents traditional stopper pushback and accidental blood exposure, setting a new safety standard in phlebotomy.

Product Specifications

  • Brand: BD (Becton, Dickinson and Company)
  • Tube Type: Venous Serum Blood Collection Tube with Clot Activator
  • Volume: 6 mL
  • Closure: Hemogard™
  • Size: Standard 13mm x 100mm
  • Sterility: Yes, vacuum-sealed and ready for use
  • Material: Medical-grade PET plastic
  • Color Code: Red or gold (verify packaging for specific color)

Primary Uses & Clinical Applications

  • Clinical Chemistry: Ideal for panels including metabolic, renal, hepatic, and lipid profiles.
  • Serology & Immunology: Used for antibody and antigen testing, infection screening, and immunoassays.
  • Routine Medical Testing: Supports general patient screening, wellness panels, and annual physicals.
  • Research & Reference Labs: Delivers reproducible, gold standard results for serum studies across applications.

Key Benefits

  • Rapid, complete clot formation for high-quality serum yields
  • Hemogard closure reduces exposure risk, enhancing lab staff safety
  • Ensures standardized, reliable results—every time
  • Bulk box of 100 maximizes efficiency in high-volume labs and hospitals
  • Fully compatible with automated analyzers and standard phlebotomy trays

Top Medical Search Terms

  • BD Vacutainer serum tube
  • serum blood collection tube
  • clot activator blood tube
  • 6 mL blood collection tube
  • Hemogard closure blood tube
  • venous blood draw tube
  • clinical chemistry blood tube
  • serum separator tube
  • phlebotomy supplies
  • laboratory blood collection tube
  • red top blood tube
  • blood sample tube for serum testing
  • high accuracy blood test tube
  • medical blood collection supplies
  • hospital laboratory supplies
  • blood tube for immunology
  • advanced blood collection tube
  • serum sample collection
  • latex-free blood collection tube
  • best blood tube for chemistry panels

Choose BD Vacutainer Plus for Unrivaled Accuracy, Safety, and Laboratory Efficiency

Thousands of healthcare professionals rely on BD Vacutainer Plus Venous Serum Blood Collection Tubes with Clot Activator, 6 mL Hemogard Closure for flawless sample integrity, superior safety, and precise test results. Transform your blood collection process and elevate patient care with the trusted leader in laboratory diagnostics.

Buy BD Vacutainer Plus Serum Blood Collection Tubes (6 mL, Hemogard Closure, 100/Box) today and set a new standard of accuracy and safety for your laboratory or clinical practice!

FAQs About Vacutainer Tubes
  • What Are Vacutainer Tubes?

    Vacutainer tubes are specialized, sterile blood collection tubes designed for safe, reliable, and contamination-free blood draws and specimen handling. These color-coded, single-use tubes ensure accurate diagnostic testing in hospitals, medical labs, clinics, and phlebotomy centers.

  • How are Vacutainer Tubes Used?

    Blood is drawn from the patient using a needle attached to a special holder. Tube is inserted into the holder; the vacuum draws the correct amount of blood into the tube. Tube is gently inverted (if required) to mix the blood with the additive. Tubes are labeled and sent to the laboratory for analysis.

  • Advantages of Vacutainer Tubes

    Safety: Minimizes exposure to blood. Efficiency: Allows multiple tubes to be drawn in a single venipuncture (“multiple draw” system). Accuracy: Delivers the correct volume for standardized testing.

  • Do Vacutainers Need to Be Sterile?

    Yes! Vacutainer tubes are sterile and individually sealed to prevent contamination and ensure accurate blood test results.

  • What is the Correct Order of Draw for a Vacutainer?

    Order of draw (to prevent cross-contamination): Blood culture bottles (yellow or SPS) Light blue (citrate) Red (serum, glass) Gold/Tiger top (SST, serum separator) Green (heparin) Lavender/Purple (EDTA) Gray (fluoride/oxalate)

  • What Do the Colors on Vacutainer Tubes Mean?

    Each color represents a different additive and test type: Yellow: Blood cultures, sterile Light Blue: Sodium citrate, coagulation studies (PT, aPTT) Red: No additive/Clot activator, chemistry/serology Gold/Tiger (SST): Serum separator (chemistry panels) Green: Heparin, plasma chemistry Lavender/Purple: EDTA, hematology (CBC) Gray: Sodium fluoride/potassium oxalate, glucose testing

  • Can Vacutainers Be Reused?

    No. Vacutainer tubes are single-use only to prevent infection, cross-contamination, and ensure accurate lab results.

  • How to Sterilize a Vacutainer?

    Do not attempt to sterilize or reuse. Always utilize new, sterile vacutainer tubes for each blood draw.

  • Where to Discard Vacutainer Tube?

    Dispose of used and expired vacutainers in a biohazard sharps container, as per OSHA and CDC safety protocols.

  • How Many Times Should an EDTA Tube Be Inverted?

    Gently invert the EDTA (lavender top) tube 8–10 times to mix the blood with the anticoagulant for accurate results.

  • What Are Common Phlebotomy Errors?

    Incorrect order of draw Insufficient mixing of tubes Underfilling or overfilling tubes Using expired tubes Hemolysis from poor technique Mislabeling specimens

  • What Color Lab Tube Do You Draw First?

    The blood culture (yellow/SPS) bottle is always drawn first to avoid contamination, followed by the light blue citrate tube.

  • What is a Grey Top Vacutainer Used For?

    Grey top tubes contain sodium fluoride and potassium oxalate and are used for glucose and lactate testing, as they prevent sugar breakdown in the sample.

  • What Color Should Blood Be When Drawn?

    Blood should appear dark red (venous) or bright red (arterial), based on the draw. Abnormal colors may indicate clinical problems.

  • Does a Vacutainer Expire?

    Yes, each vacutainer has an expiration date for sterility and additive effectiveness—never use expired tubes for specimen collection.

  • What Can Happen if Vacutainers Are Mixed Vigorously?

    Vigorous mixing causes hemolysis (rupture of red blood cells) and sample rejection. Always invert gently as instructed.

  • Are Vacutainers Single Use Only?

    Absolutely. Never reuse; always discard after a single blood draw to maintain patient safety and sample integrity.

  • What Temperature Should a Vacutainer Be Stored At?

    Store vacutainer tubes at room temperature (15°C–25°C / 59°F–77°F) in a dry, cool place away from direct sunlight and moisture.

  • How to Dispose of Expired Vacutainers?

    Expired vacutainers are disposed of in a biohazard sharps or chemical waste container per your lab’s safety policy.

  • How to Memorize Order of Draw Phlebotomy?

    Use the mnemonic: "Boys Love Ravishing Girls Like Dieters Love Greek Yogurt" (Blood culture, Light blue, Red, Gold, Light green, Dark green, Lavender, Gray, Yellow).

  • What Happens if You Underfill an EDTA Tube?

    Underfilling alters the blood-to-anticoagulant ratio, skewing hematology test results (like CBC). Always fill tubes to designated mark.

  • What is SST in Phlebotomy?

    SST (Serum Separator Tube) contains a gel that separates blood serum from cells after centrifugation. Used for chemistry panels, serology, and immunology tests.

  • What Labs Go in What Color Tubes?

    Blood culture (yellow): Microbiology Light blue: Coagulation (PT, aPTT) Red/Gold/Tiger: Chemistry, serology, immunology Green: Plasma chemistry (troponin, ammonia) Lavender/Purple: Hematology (CBC, HbA1c) Gray: Glucose testing

  • Why Choose Our Vacutainer Tubes?

    Sterile, single-use vacuum tubes for perfect blood collection Accurate color-coded labeling for error-free phlebotomy Leak-proof, shatter-resistant and tamper-evident design Trusted by hospitals, labs, clinics, and research facilities Compatible with all leading blood collection systems Available in all standard sizes and additives

Search Any Type of Product, Medication, or Alignment