Skip to content
New users? Get 5% off on your first purchase.
Free US shipping over $100
New users? Get 5% off on your first purchase.
Free US shipping over $100

Added to your cart:

Cart subtotal

Clearlink Y-Type IV Catheter Extension Set, 2 Slide Clamps, 6.5" length

SKU INS1530085
Sale 23%
Original price $ 12.75
Current price $ 9.79
Fast Delivery
Fast Delivery
24/7 Support
24/7 Support
Easy Returns
Easy Returns
Hospital Grade
Hospital Grade
Save 23% ($ 2.96)
Free Shipping on orders $100
Returns 30-day return / replacement
Payment Secure transaction
Packaging Ships in product packaging
Service-Disabled Veteran-Owned Small Business
Service-Disabled Veteran-Owned Small Business
Located in Adirondack Mountains in NY
Located in Adirondack Mountains in NY
Family Owned Business 2002
Family Owned Business 2002
Sale 23%
Original price $ 12.75
Current price $ 9.79
Free Shipping on orders $100
Returns 30-day return / replacement
Payment Secure transaction
Packaging Ships in product packaging
Clearlink Y-Type IV Catheter Extension Set, 2 Slide Clamps, 6.5" length
Clearlink Y-Type IV Catheter Extension Set, 2 Slide Clamps, 6.5" length
$ 12.75 $ 9.79
Description

The Clearlink Y-Type IV Catheter Extension Set by Baxter Healthcare 2N8377 is expertly designed for efficient, safe, and flexible intravenous therapy. Featuring a sterile 6.5-inch standard bore tubing, two secure slide clamps, and a Clearlink Luer-activated valve, this disposable set enhances infection control and workflow efficiency. Its innovative Y-type configuration and rotating male luer lock adapter ensure precise connections and multi-site access for infusion, medication delivery, and sampling—all with the trusted quality of Baxter.

What is it Used For?

This Baxter Clearlink Y-Type Extension Set is used for:

  • Extension of IV catheters: Enhancing access and flexibility in IV tubing, especially in difficult-to-reach areas
  • Dual-site infusion: Allowing simultaneous or alternating administration of fluids or medications through Y-type injection ports
  • Medication injection or sampling: Via needleless Clearlink luer-activated valves, reducing infection risk and needlestick injuries
  • Efficient fluid management: For acute, critical, or general care in hospital and clinical settings

Details & Features

  • Product Number: 2N8377
  • Y-Type Configuration: Dual access points optimize multi-infusion capability
  • Clearlink Luer-Activated Valve: Enables safe, needle-free injections and sampling, promoting infection prevention
  • Priming Volume: 1.2 mL—account for precise medication dosing and minimal fluid waste
  • Tube Length: 6.5 inches (standard bore)—ideal for patient comfort and secure placement
  • Clamps: 2 easy-to-use slide clamps for safe fluid control and secure line management
  • Connector: Male luer lock adapter with retractable, rotating collar for leak-resistant, secure connection
  • Color: Transparent for easy visualization of flow and air bubbles
  • Latex-Free: Not made with natural rubber latex—reduced risk for allergic reactions
  • Sterile, Single-Use: Strict infection control—disposable after one use
  • Retractable Collar: Added safety and ease at connection point

Directions

  1. Prepare: Inspect packaging for damage or contamination before opening. Ensure the expiration date is valid.
  2. Connection: Attach the male luer lock adapter with rotating collar securely to the IV catheter or primary line. Ensure the collar is fully engaged.
  3. Priming: Prime the set by opening slide clamps and flushing IV solution through the tubing until all air is removed (1.2 mL priming volume).
  4. Y-Port Access: Utilize Clearlink luer-activated Y-ports for needleless injection or sampling. Disinfect each port before access, using aseptic technique.
  5. Clamping: Use slide clamps to control or temporarily halt fluid flow as needed during medication administration or when disconnecting.
  6. Disposal: Dispose after single use according to facility protocol.

Warnings

  • Single-use only: Do not reuse. Reuse increases risk of infection, biofilm formation, or device failure.
  • Sterility required: Use only if packaging is intact and undamaged. Discard if sterility is compromised.
  • Priming volume: Always account for the 1.2 mL priming volume in medication calculations to avoid dosing errors.
  • Needleless ports: Use only compatible luer lock syringes and IV equipment for injection or withdrawal.
  • Proper technique: Always use aseptic technique during installation, access, and disconnection to minimize infection risk.
  • Latex-free: Although latex is not used, always confirm patient allergies before IV therapy.
  • Storage: Store in a cool, dry place and do not use past the expiration date.

Choose the Baxter Clearlink Y-Type IV Catheter Extension Set (2N8377) for reliable, safe, and flexible IV access in any critical or general care setting. Trust Baxter Healthcare’s innovation for patient-focused, infection-resistant IV therapy.