IV Administration Set 20 Drop with Y-Port Injection Sites, 92" Length

Bacteriostatic Water Injection by Hospira, Multiple Dose Vials 30 mL 25/Pack (Rx)
$ 539.00
IV Bags, IV Fluid Solution for Intravenous & Infusion IV Therapy (Rx)
$ 10.95
Exel IV Administration Set, Y-Injection Site, 78" Tube, Roller Clamp
$ 1.99
Bacteriostatic Sodium Chloride 0.9% Saline Injection Multiple Dose 30 ml x 25/Pack (Rx)
$ 125.00
MI Paste with Mint Flavor Remineralizing Toothpaste by GC America
$ 23.00
Mi Paste One Anti-Cavity Toothpaste, Fresh Mint by GC America
$ 24.00
Alcohol Prep Pads Sterile by Dynarex 200/Box
$ 2.49
Nitrile Powder Free Examination Gloves Blue Color, 100/Box
$ 7.95
Albuterol Sulfate 0.083% Inhalation Nebulizer Solution 2.5 mg/3 ml 25/Box (Rx)
$ 18.50
IV Set 15 Drop Luer Lock with 78" Tubing, Roller Clamp, and Y-Injection Site Ports
$ 1.99
Sale 28%
Sale 46%
Sale 37%
Sale 35%
Sale 27%
Sale
Sale 37%
Sale
Sale
🔒 Medical License Required
Sale
🔒 Medical License Required
Sale 10%
🔒 Medical License Required
Sale
Sale 38%
Sale 46%
Sale 50%
Sale
🔒 Medical License Required
Sale
🔒 Medical License Required
Sale
🔒 Medical License Required
Sale 30%
🔒 Medical License Required
Sale 28%
🔒 Medical License Required
Sale 44%
🔒 Medical License Required
This item is sold out
🔒 Medical License Required
Sale
Sale 38%
Sale 24%
The IV Administration Set with 20 Drop and Y-Port Injection Sites is utilized for intravenous infusion of fluids and medications, providing accurate control over infusion rates. The Y-port injection sites allow for the administration of additional medications without disrupting the flow of ongoing infusions. With a length of 92”, this set offers extended reach and flexibility for convenient patient positioning in clinical and hospital environments. Its design enhances patient safety and ensures efficient and reliable drug delivery.
Use the formula:
Flow rate (gtt/min) = [Volume (mL) x Drop Factor (20 gtt/mL)] ÷ Time (min)
For example: 1000 mL over 4 hours
1000 x 20 ÷ (4 x 60) = 83 gtt/min
A 20 drop set is typically used in adults for general infusions where faster flow rates are needed. A 60 drop microdrip set is preferred when precise, slower rates are required (pediatrics, critical medications).
The Dynarex IV Administration Set with 20 Drop drip configuration is a versatile and reliable solution for delivering intravenous fluids and medications. Designed for optimal performance in various medical settings, this set includes convenient Y-Port injection sites and an extended length of 92 inches, promoting ease of use and enhanced patient care.
Key Features
20 Drop Drip Rate:
Y-Port Injection Site
92" Length:
Specifications
Usage and Application
General IV Therapy:
Suitable for routine intravenous therapy, the set supports the delivery of both fluids and medications with accuracy.
Professional Healthcare Settings:
Safety and Handling
The Dynarex IV Administration Set with its 20 drop capability, Y-Port injection sites, and extended length is an essential tool in providing precise and flexible intravenous therapy solutions in various medical environments.
The IV Administration Set with 20 Drop and Y-Port Injection Sites is utilized for intravenous infusion of fluids and medications, providing accurate control over infusion rates. The Y-port injection sites allow for the administration of additional medications without disrupting the flow of ongoing infusions. With a length of 92”, this set offers extended reach and flexibility for convenient patient positioning in clinical and hospital environments. Its design enhances patient safety and ensures efficient and reliable drug delivery.
Use the formula:
Flow rate (gtt/min) = [Volume (mL) x Drop Factor (20 gtt/mL)] ÷ Time (min)
For example: 1000 mL over 4 hours
1000 x 20 ÷ (4 x 60) = 83 gtt/min
A 20 drop set is typically used in adults for general infusions where faster flow rates are needed. A 60 drop microdrip set is preferred when precise, slower rates are required (pediatrics, critical medications).
The Dynarex IV Administration Set with 20 Drop drip configuration is a versatile and reliable solution for delivering intravenous fluids and medications. Designed for optimal performance in various medical settings, this set includes convenient Y-Port injection sites and an extended length of 92 inches, promoting ease of use and enhanced patient care.
Key Features
20 Drop Drip Rate:
Y-Port Injection Site
92" Length:
Specifications
Usage and Application
General IV Therapy:
Suitable for routine intravenous therapy, the set supports the delivery of both fluids and medications with accuracy.
Professional Healthcare Settings:
Safety and Handling
The Dynarex IV Administration Set with its 20 drop capability, Y-Port injection sites, and extended length is an essential tool in providing precise and flexible intravenous therapy solutions in various medical environments.
Great customer service
Arrived promptly
These are great! I also like that I don't need a prescription to order them as they're for my cat.
IV Administration Set 20 Drop with Y-Port Injection Sites, 92" Length
Just the product we needed for our elderly cat who receives fluids every day. Very affordable and fast delivery.
got my IV sets quickly and for a great price. thank you!
IV Administration Set 20 Drop with Y-Port Injection Sites, 92" Length
Great
IV Administration Set 20 Drop with Y-Port Injection Sites, 92" Length
You guys are the best!
A 20 drop IV administration set delivers 1 mL of fluid for every 20 drops (“gtt” is the abbreviation for “guttae,” meaning drops). It is commonly called a macrodrip set and is used for general fluid and medication administration.
Key components include the spike (for the IV bag), drip chamber, tubing, flow regulator or roller clamp, injection ports, and Luer lock or slip tip connector.
A 20 drop set is typically used in adults for general infusions where faster flow rates are needed. A 60 drop microdrip set is preferred when precise, slower rates are required (pediatrics, critical medications).
Use the formula: Flow rate (gtt/min) = [Volume (mL) x Drop Factor (20 gtt/mL)] ÷ Time (min) For example: 1000 mL over 4 hours 1000 x 20 ÷ (4 x 60) = 83 gtt/min
Spike the IV bag, squeeze and fill the drip chamber halfway, open the roller clamp, and allow fluid to flow through the tubing until all air is expelled before connecting to the patient.
Yes, macrodrip sets like the 20 gtt/mL are often used for blood and blood product transfusions because they allow adequate flow.
Usually, microdrip (60 gtt/mL) sets are preferred in pediatrics for more precise dosing, but a 20 gtt/mL set might be used in certain emergency or high-volume situations under strict supervision.
Common lengths are 83–105 inches, but this can vary by manufacturer.
Many are compatible, but always verify compatibility with the specific pump and manufacturer guidelines.
Always observe proper aseptic technique, check for air bubbles, monitor flow rates, and regularly inspect the site for infiltration or phlebitis.
Yes, IV administration sets are designed for single use and should be disposed of according to infection control guidelines after use.
Something went wrong. Please try again.
Check your email for exclusive offers and updates from Mountainside Medical.
Are you sure you want to cancel your payment? Your cart is still saved.
You need an account to add products to your wishlist. Log in or create an account to start saving your favorites.
